Calculate induced emf per phase for full pitch winding in a 3 phase, 8 pole, star connected alternator.
Q. A 3 phase, 50 Hz, 8 pole, star connected alternator has 120 slots having 10 conductors per slot. The flux per pole is 0.02 Wb and distributed sinusoidally. The induced emf per phase for full pitch winding is- Published on 27 Oct 15a. 849.816 V
b. 956.782 V
c. 1046.812 V
d. None of these
ANSWER: 849.816 V