Numerical - Coal consumption per hour for the station delivering full rated output
Q. A 100 MW steam station uses coal of calorific value of 5780 kcal/kg. The thermal efficiency is about 30% and the electrical efficiency is 93%. What would be the coal consumption per hour, when the station is delivering its full rated output?- Published on 19 Nov 15a. 48672 kg
b. 53330 kg
c. 71876 kg
d. 31826 kg
ANSWER: 53330 kg