Essentials Of Indicating Instrument - 1 - MCQs with answers
Q1. The electromagnetic effect is generally utilized forA. Ammeters
B. Voltmeters
C. Wattmeters and watt-hour meters
D. All of these
View Answer / Hide AnswerQ2. The electrostatic effect is utilized forA. Ammeters
B. Voltmeters
C. D.C. ampere-hour meters
D. Wattmeters
View Answer / Hide AnswerQ3. Integrating instruments is the subdivision of the secondary instruments. The example for integrating instruments isA. Ampere-hour meters
B. Watt-hour meters
C. Wattmeters
D. Ampere-hour and watt-hour meters
View Answer / Hide AnswerANSWER: D. Ampere-hour and watt-hour meters
Q4. The moving system in the indicating instruments is subjected toA. Deflecting torque
B. Controlling torque
C. Damping torque
D. All the above
View Answer / Hide AnswerQ5. If the deflection torques on moving system increases then the controlling torqueA. Increases
B. Decreases
C. Remains same
D. None of these
View Answer / Hide AnswerQ6. In the absence of the restoring torque, the pointerA. Will not deflect from its initial position
B. Will deflect but would not return to its zero position on removing current
C. Will deflect and return to its zero position on removing current
D. Will swing from minimum to maximum position
View Answer / Hide AnswerANSWER: B. Will deflect but would not return to its zero position on removing current
Q7. In indicating instruments, the controlling and restoring torque can be obtained by usingA. Spring
B. Gravity
C. Either by spring or by gravity
D. Neither by spring nor by gravity
View Answer / Hide AnswerANSWER: C. Either by spring or by gravity
Q8. The restoring torque in a spring controlled indicating instrument isA. Directly proportional to the angle of deflection of moving system
B. Directly proportional to the sine of angle of deflection of moving system
C. Inversely proportional to the angle of deflection of moving system
D. Directly proportional to the square of the angle of deflection of moving system
View Answer / Hide AnswerANSWER: A. Directly proportional to the angle of deflection of moving system
Q9. The deflecting torque in a permanent magnet moving coil type instrument isA. Directly proportional to the angle of deflection of moving system
B. Directly proportional to the current flowing through it
C. Directly proportional to the current flowing through it
D. Inversely proportional to the current flowing through it
View Answer / Hide AnswerANSWER: B. Directly proportional to the current flowing through it
Q10. The spring which is used for producing controlling torque in indicating instruments are made up of materials which is/areA. Non-magnetic
B. Not subjected to much fatigue
C. Low specific resistance and low temperature resistance coefficient
D. All of these
View Answer / Hide Answer