Position & Level Transducers - MCQs with answers

Position & Level Transducers - MCQs with answers


1. Determine the output voltage of a resistance position transducer when wiper is 8cm with the utilized shaft stroke level of about 20 cm from another end under the input voltage application of 10V with the total resistance value of potentiometer estimated to 6V.

a. 2V
b. 4V
c. 6V
d. 8 V

View Answer / Hide Answer

ANSWER: d. 8 V



2. The bonding cement used in the fabrication process of strain gauge should possess _________

a. high insulation resistance with better strain transmissibility

b. low insulation resistance with better strain transmissibility

c. low insulation resistance with better stress transmissibility

d. high insulation resistance with better stress transmissibility

View Answer / Hide Answer

ANSWER: a. high insulation resistance with better strain transmissibility



3. What kind of bonding cement is supposed to get cured instantaneously in the fabrication process of strain -gauge used as a pressure measuring transducer?

a. Duco Cement
b. Epoxy Cement
c. Acrylic Cement
d. Phenolic Bakellite Cement

View Answer / Hide Answer

ANSWER: c. Acrylic Cement


Post your comment