Special Purpose Measuring Instruments - MCQs with answers
Q1. Ballistic galvanometer are principally used for the measurement ofA. Current
B. Voltage
C. Power
D. Electric charges
View Answer / Hide AnswerANSWER: D. Electric charges
Q2. Vibration galvanometer are generally used A. For measuring electric charges
B. As null-point detectors in ac bridges
C. As null-point detectors in dc bridges
D. For measuring power
View Answer / Hide AnswerANSWER: B. As null-point detectors in ac bridges
Q3. The meter of a vibrating reed frequency meter depends for its indications on theA. Electrical resonance of thin flat steel reeds
B. Mechanical resonance of thin flat steel reeds
C. Mechanical resonance of thick flat steel reeds
D. Electrical resonance of thick flat steel reeds
View Answer / Hide AnswerANSWER: B. Mechanical resonance of thin flat steel reeds
Q4. The electrodynamic frequency meters haveA. Linear scale and their readings does not depends on voltage
B. Linear scale and their readings depends on voltage
C. Non linear scale and their readings does not depends on voltage
D. Non linear scale and their readings depends on voltage
View Answer / Hide AnswerANSWER: A. Linear scale and their readings does not depends on voltage
Q5. A moving iron frequency meter consists ofA. Two inductive circuits connected in parallel
B. One inductive and one non inductive circuit connected in parallel
C. Two non inductive circuits connected in parallel
D. One inductive and one non inductive circuit connected in series
View Answer / Hide AnswerANSWER: B. One inductive and one non inductive circuit connected in parallel
Q6. If the frequency of electrodynamic power factor meter is doubled then its reading will becomeA. Twice of the original reading
B. Half of the original reading
C. Four times of the original reading
D. Remains unaffected
View Answer / Hide AnswerANSWER: D. Remains unaffected
Q7. Moving iron power factor meter are suitable for 3 phase balanced circuits. It consists ofA. One control spring
B. Two control spring
C. Three control spring
D. No control spring
View Answer / Hide AnswerANSWER: D. No control spring
Q8. In Nalder-Lipman moving iron power factor meter, the magnetic field producedA. Rotates in clockwise direction
B. Rotates in anticlockwise direction
C. Rotates in both clockwise and anticlockwise direction alternately
D. No rotating magnetic field is produced
View Answer / Hide AnswerANSWER: A. Rotates in clockwise direction
Q9. A series reactance coil is used in Weston frequency meter. This coil is used toA. Suppress harmonics present in the current flowing through the meter
B. Minimizes the waveform errors
C. Both (a) and (b)
D. None of these
View Answer / Hide AnswerANSWER: C. Both (a) and (b)
Q10. The coils of rotating type phase sequence indicator are mounted atA. 60 degree apart in space
B. 90 degree apart in space
C. 120 degree apart in space
D. 180 degree apart in space
View Answer / Hide AnswerANSWER: C. 120 degree apart in space